autohotkey - 변수리스트(Variables and Expressions) 모음
http://www.autohotkey.com/docs/Variables.htm
Variables and Expressions
Table of Contents
- Variables
- Expressions
- Operators in Expressions
- Built-in Variables
- Environment Variables vs. Normal Variables
- Variable Capacity and Memory
Variables
Variable types: AutoHotkey has no explicitly defined variable types. However, a variable containing only digits (with an optional decimal point) is automatically interpreted as a number when a math operation or comparison requires it. (To improve performance, numbers are cached internally to avoid conversions to/from strings.)
Variable scope and declarations: With the exception of local variables in functions, all variables are global; that is, their contents may be read or altered by any part of the script. Except where noted on the functions page, variables are not declared; they come into existence simply by using them (and each variable starts off empty/blank).
Variable names: Variable names are not case sensitive (for example, CurrentDate is the same as currentdate). Variable names may be up to 253 characters long and may consist of letters, numbers and the following punctuation: # _ @ $ ? [ ]
Due to style conventions, it is generally better to name your variables using only letters, numbers, and the underscore character (for example: CursorPosition, Total_Items, and entry_is_valid). This style allows people familiar with other computer languages to understand your scripts more easily. Also, if you use the same conventions in AutoHotkey as you use in other languages, you may find it easier to re-read your own scripts.
Although a variable name may consist entirely of digits, this is generally used only for incoming command line parameters. Such numeric names cannot be used in expressions because they would be seen as numbers rather than variables.
Since the words AND, OR, and NOT are used as operators in expressions, generally they should not be used as variable names. Using such names in an expression would prevent proper evaluation.
Storing values in variables: To store a string or number in a variable, there are two methods: traditional and expression. The traditional method uses the equal sign operator (=) to assign unquoted literal strings or variables enclosed in percent signs. For example:
MyNumber = 123
MyString = This is a literal string.
CopyOfVar = %Var% ; With the = operator, percent signs are required to retrieve a variable's contents.
By contrast, the expression method uses the colon-equal operator (:=) to store numbers, quoted strings, and other types of expressions. The following examples are functionally identical to the previous ones:
MyNumber := 123
MyString := "This is a literal string."
CopyOfVar := Var ; Unlike its counterpart in the previous section, percent signs are not used with the := operator.
The latter method is preferred by many due to its greater clarity, and because it supports an expression syntax nearly identical to that in many other languages.
You may have guessed from the above that there are two methods to erase the contents of a variable (that is, to make it blank):
MyVar = MyVar := ""
The empty pair of quotes above should be used only with the := operator because if it were used with the = operator, it would store two literal quote-characters inside the variable.
Retrieving the contents of variables: Like the two methods of storing values, there are also two methods for retrieving them: traditional and expression. The traditional method requires that each variable name be enclosed in percent signs to retrieve its contents. For example:
MsgBox The value in the variable named Var is %Var%. CopyOfVar = %Var%
By contrast, the expression method omits the percent signs around variable names, but encloses literal strings in quotes. Thus, the following are the expression equivalents of the previous examples:
MsgBox % "The value in the variable named Var is " . Var . "." ; A period is used to concatenate (join) two strings.
CopyOfVar := Var
In the MsgBox line above, a percent sign and a space is used to change the parameter from traditional to expression mode. This is necessary because the traditional method is used by default by all commands (except where otherwise documented). However, certain parameters of some commands are documented as accepting expressions, in which case the leading percent sign is permitted but not necessary. For example, all of the following are effectively identical because Sleep's first parameter is expression-capable:
Sleep MillisecondsToWait Sleep %MillisecondsToWait% Sleep % MillisecondsToWait
Comparing variables: Please read the expressions section below for important notes about the different kinds of comparisons, especially about when to use parentheses.
Expressions
Expressions are used to perform one or more operations upon a series of variables, literal strings, and/or literal numbers.
Variable names in an expression are not enclosed in percent signs (except for arrays and other double references). Consequently, literal strings must be enclosed in double quotes to distinguish them from variables. For example:
if (CurrentSetting > 100 or FoundColor <> "Blue") MsgBox The setting is too high or the wrong color is present.
In the example above, "Blue" appears in quotes because it is a literal string. To include an actual quote-character inside a literal string, specify two consecutive quotes as shown twice in this example: "She said, ""An apple a day."""
Important: An if-statement that contains an expression is differentiated from a traditional if-statement such as If FoundColor <> Blue by making the character after the word "if" an open-parenthesis. Although this is usually accomplished by enclosing the entire expression in parentheses, it can also be done with something like if (x > 0) and (y > 0). In addition, the open-parenthesis may be omitted entirely if the first item after the word "if" is a function call or an operator such as "not" or "!".
Empty strings: To specify an empty string in an expression, use an empty pair of quotes. For example, the statement if (MyVar <> "") would be true if MyVar is not blank. However, in a traditional-if, a pair of empty quotes is treated literally. For example, the statement if MyVar = "" is true only if MyVar contains an actual pair of quotes. Thus, to check if a variable is blank with a traditional-if, use = or <> with nothing on the right side as in this example: if Var =
On a related note, any invalid expression such as (x +* 3) yields an empty string.
Storing the result of an expression: To assign a result to a variable, use the := operator. For example:
NetPrice := Price * (1 - Discount/100)
Boolean values: When an expression is required to evaluate to true or false (such as an IF-statement), a blank or zero result is considered false and all other results are considered true. For example, the statement "if ItemCount" would be false only if ItemCount is blank or 0. Similarly, the expression "if not ItemCount" would yield the opposite result.
Operators such as NOT/AND/OR/>/=/< automatically produce a true or false value: they yield 1 for true and 0 for false. For example, in the following expression, the variable Done is assigned 1 if either of the conditions is true:
Done := A_Index > 5 or FoundIt
As hinted above, a variable can be used to hold a false value simply by making it blank or assigning 0 to it. To take advantage of this, the shorthand statement "if Done" can be used to check whether the variable Done is true or false.
The words true and false are built-in variables containing 1 and 0. They can be used to make a script more readable as in these examples:
CaseSensitive := false ContinueSearch := true
Integers and floating point: Within an expression, numbers are considered to be floating point if they contain a decimal point; otherwise, they are integers. For most operators -- such as addition and multiplication -- if either of the inputs is a floating point number, the result will also be a floating point number.
Within expressions and non-expressions alike, integers may be written in either hexadecimal or decimal format. Hexadecimal numbers all start with the prefix 0x. For example, Sleep 0xFF is equivalent to Sleep 255. In v1.0.46.11+, floating point numbers written in scientific notation are recognized; but only if they contain a decimal point (e.g. 1.0e4 and -2.1E-4).
Force an expression: An expression can be used in a parameter that does not directly support it (except an OutputVar or InputVar parameter such as those of StringLen) by preceding the expression with a percent sign and a space or tab. This technique is often used to access arrays. For example:
FileAppend, % MyArray%i%, My File.txt MsgBox % "The variable MyVar contains " . MyVar . "." Loop % Iterations + 1 WinSet, Transparent, % X + 100 Control, Choose, % CurrentSelection - 1
Operators in Expressions
Operators of equal precedence such as multiply (*) and divide (/) are evaluated in left-to-right order unless otherwise specified below. By contrast, an operator of lower precedence such as add (+) is evaluated after a higher one such as multiply (*). For example, 3 + 2 * 2 is evaluated as 3 + (2 * 2). Parentheses may be used to override precedence as in this example: (3 + 2) * 2
Except where noted below, any blank value (empty string) involved in a math operation is not assumed to be zero. Instead, it is treated as an error, which causes that part of the expression to evaluate to an empty string. For example, if the variable X is blank, the expression X+1 yields a blank value rather than 1.
Expression Operators (in descending precedence order)
%Var% |
If a variable is enclosed in percent signs within an expression (e.g. %Var%), whatever that variable contains is assumed to be the name or partial name of another variable (if there is no such variable, %Var% resolves to a blank string). This is most commonly used to reference array elements such as the following example: Var := MyArray%A_Index% + 100 Such a reference should not resolve to an environment variable, the clipboard, or any reserved/read-only variable. If it does, it is treated as an empty string. Also, for backward compatibility, command parameters that are documented as "can be an expression" treat an isolated name in percent signs (e.g. %Var%, but not Array%i%) as though the percent signs are absent. This can be avoided by enclosing the reference in parentheses; e.g. Sleep (%Var%) |
++ -- |
Pre- and post-increment/decrement. Adds or subtracts 1 from a variable (but in versions prior to 1.0.46, these can be used only by themselves on a line; no other operators may be present). The operator may appear either before or after the variable's name. If it appears before the name, the operation is performed immediately and its result is used by the next operation. For example, Var := ++X increments X immediately and then assigns its value to Var. Conversely, if the operator appears after the variable's name, the operation is performed after the variable is used by the next operation. For example, Var := X++ increments X only after assigning the current value of X to Var. Due to backward compatibility, the operators ++ and -- treat blank variables as zero, but only when they are alone on a line; for example, y:=1, ++x and MsgBox % ++x both produce a blank result when x is blank. |
** | Power. Both the base and the exponent may contain a decimal point. If the exponent is negative, the result will be formatted as a floating point number even if the base and exponent are both integers. Since ** is of higher precedence than unary minus, -2**2 is evaluated like -(2**2) and so yields -4. Thus, to raise a literal negative number to a power, enclose it in parentheses such as (-2)**2. Note: A negative base combined with a fractional exponent such as (-2)**0.5 is not supported; it will yield an empty string. But both (-2)**2 and (-2)**2.0 are supported. |
- ! ~ & * |
Unary minus (-): Although it uses the same symbol as the subtract operator, unary minus applies to only a single item or sub-expression as shown twice in this example: -(3 / -x). On a related note, any unary plus signs (+) within an expression are ignored. Logical-not (!): If the operand is blank or 0, the result of applying logical-not is 1, which means "true". Otherwise, the result is 0 (false). For example: !x or !(y and z). Note: The word NOT is synonymous with ! except that ! has a higher precedence. In v1.0.46+, consecutive unary operators such as !!Var are allowed because they are evaluated in right-to-left order. Bitwise-not (~): This inverts each bit of its operand. If the operand is a floating point value, it is truncated to an integer prior to the calculation. If the operand is between 0 and 4294967295 (0xffffffff), it will be treated as an unsigned 32-bit value. Otherwise, it is treated as a signed 64-bit value. For example, ~0xf0f evaluates to 0xfffff0f0 (4294963440). Address (&): &MyVar retrieves the address of MyVar's contents in memory, which is typically used with DllCall structures. &MyVar also disables the caching of binary numbers in that variable, which can slow down its performance if it is ever used for math or numeric comparisons. Caching is re-enabled for a variable whenever its address changes (e.g. via VarSetCapacity()). Dereference (*): *Expression assumes that Expression resolves to a numeric memory address; it retrieves the byte at that address as a number between 0 and 255 (0 is always retrieved if the address is 0; but any other invalid address must be avoided because it might crash the script). However, NumGet() generally performs much better when retrieving binary numbers. |
* / // |
Multiply (*): The result is an integer if both inputs are integers; otherwise, it is a floating point number. True divide (/): Unlike EnvDiv, true division yields a floating point result even when both inputs are integers. For example, 3/2 yields 1.5 rather than 1, and 4/2 yields 2.0 rather than 2. Floor divide (//): The double-slash operator uses high-performance integer division if the two inputs are integers. For example, 5//3 is 1 and 5//-3 is -1. If either of the inputs is in floating point format, floating point division is performed and the result is truncated to the nearest integer to the left. For example, 5//3.0 is 1.0 and 5.0//-3 is -2.0. Although the result of this floating point division is an integer, it is stored in floating point format so that anything else that uses it will see it as such. For modulo, see mod(). The *= and /= operators are a shorthand way to multiply or divide the value in a variable by another value. For example, Var*=2 produces the same result as Var:=Var*2 (though the former performs better). Division by zero yields a blank result (empty string). |
+ - |
Add (+) and subtract (-). On a related note, the += and -= operators are a shorthand way to increment or decrement a variable. For example, Var+=2 produces the same result as Var:=Var+2 (though the former performs better). Similarly, a variable can be increased or decreased by 1 by using Var++, Var--, ++Var, or --Var. |
<< >> |
Bit shift left (<<) and right (>>). Example usage: Value1 << Value2. Any floating point input is truncated to an integer prior to the calculation. Shift left (<<) is equivalent to multiplying Value1 by "2 to the Value2th power". Shift right (>>) is equivalent to dividing Value1 by "2 to the Value2th power" and rounding the result to the nearest integer leftward on the number line; for example, -3>>1 is -2. |
& ^ | |
Bitwise-and (&), bitwise-exclusive-or (^), and bitwise-or (|). Of the three, & has the highest precedence and | has the lowest. Any floating point input is truncated to an integer prior to the calculation. |
. |
Concatenate. The period (dot) operator is used to combine two items into a single string (there must be at least one space on each side of the period). You may also omit the period to achieve the same result (except where ambiguous such as x -y, or when the item on the right side has a leading ++ or --). When the dot is omitted, there should be at least one space between the items to be merged. Sub-expressions can also be concatenated. For example: Var := "The net price is " . Price * (1 - Discount/100) A line that begins with a period (or any other operator) is automatically appended to the line above it. |
> < >= <= |
Greater (>), less (<), greater-or-equal (>=), and less-or-equal (<=). If either of the inputs is not a number, both are compared alphabetically (a quoted literal string such as "55" is always considered non-numeric in this context). The comparison is case sensitive only if StringCaseSense has been turned on. See also: Sort |
= == <> != |
Equal (=) , case-sensitive-equal (==) , and not-equal (<> or !=). The operators != and <> are identical in function. The == operator behaves identically to = except when either of the inputs is not a number, in which case == is always case sensitive and = is always case insensitive (the method of insensitivity depends on StringCaseSense). By contrast, <> and != obey StringCaseSense. Note: A quoted literal string such as "55" is always considered non-numeric in this context. |
NOT | Logical-NOT. Except for its lower precedence, this is the same as the ! operator. For example, not (x = 3 or y = 3) is the same as !(x = 3 or y = 3) |
AND && |
Both of these are logical-AND. For example: x > 3 and x < 10. To enhance performance, short-circuit evaluation is applied. Also, a line that begins with AND/OR/&&/|| (or any other operator) is automatically appended to the line above it. |
OR || |
Both of these are logical-OR. For example: x <= 3 or x >= 10. To enhance performance, short-circuit evaluation is applied. |
?: |
Ternary operator [v1.0.46+]. This operator is a shorthand replacement for the if-else statement. It evaluates the condition on its left side to determine which of its two branches should become its final result. For example, var := x>y ? 2 : 3 stores 2 in Var if x is greater than y; otherwise it stores 3. To enhance performance, only the winning branch is evaluated (see short-circuit evaluation). Note: For compatibility reasons, the question mark must have at least one space on both sides (this may be resolved in a future version). |
:= += -= *= /= //= .= |= &= ^= >>= <<= |
Assign. Performs an operation on the contents of a variable and stores the result back in the same variable (but in versions prior to 1.0.46, these could only be used as the leftmost operator on a line, and only the first five operators were supported). The simplest assignment operator is colon-equals (:=), which stores the result of an expression in a variable. For a description of what the other operators do, see their related entries in this table. For example, Var //= 2 performs floor division to divide Var by 2, then stores the result back in Var. Similarly, Var .= "abc" is a shorthand way of writing Var := Var . "abc". Unlike most other operators, assignments are evaluated from right to left. Consequently, a line such as Var1 := Var2 := 0 first assigns 0 to Var2 then assigns Var2 to Var1. If an assignment is used as the input for some other operator, its value is the variable itself. For example, the expression (Var+=2) > 50 is true if the newly-increased value in Var is greater than 50. This also allows an assignment to be passed ByRef, or its address taken; for example: &(x:="abc"). The precedence of the assignment operators is automatically raised when it would avoid a syntax error or provide more intuitive behavior. For example: not x:=y is evaluated as not (x:=y). Similarly, ++Var := X is evaluated as ++(Var := X); and Z>0 ? X:=2 : Y:=2 is evaluated as Z>0 ? (X:=2) : (Y:=2) Known limitations caused by backward compatibility (these may be resolved in a future release): 1) When /= is the leftmost operator in an expression and it is not part of a multi-statement expression, it performs floor division unless one of the inputs is floating point (in all other cases, /= performs true division); 2) Date/time math is supported by += and -= only when that operator is the leftmost one on a line; 3) The operators +=, -=, and *= treat blank variables as zero, but only when they are alone on a line; for example, y:=1, x+=1 and MsgBox % x-=3 both produce a blank result when x is blank. |
, |
Comma (multi-statement) [v1.0.46+]. Commas may be used to write multiple sub-expressions on a single line. This is most commonly used to group together multiple assignments or function calls. For example: x:=1, y+=2, ++index, func(). Such statements are executed in order from left to right. Note: A line that begins with a comma (or any other operator) is automatically appended to the line above it. See also: comma performance. In v1.0.46.01+, when a comma is followed immediately by a variable and an equal sign, that equal sign is automatically treated as an assignment (:=). For example, all of the following are assignments: x:=1, y=2, a=b=c |
mod() |
These and other built-in math functions are described here. |
Performance: The expression assignment operator (:=) is optimized so that it performs just as quickly as the non-expression operator (=) for simple cases such as the following:
x := y ; Same performance as x = %y% x := 5 ; Same performance as x = 5. x := "literal string" ; Same performance as x = literal string.
In v1.0.48+, the comma operator is usually faster than writing separate expressions, especially when assigning one variable to another (e.g. x:=y, a:=b). Performance continues to improve as more and more expressions are combined into a single expression; for example, it may be 35% faster to combine five or ten simple expressions into a single expression.
Built-in Variables
The following variables are built into the program and can be referenced by any script. With the exception of Clipboard, ErrorLevel, and command line parameters, these variables are read-only; that is, their contents cannot be directly altered by the script.
Table of Contents
- Special Characters: A_Space, A_Tab
- Script Properties: command line parameters, A_WorkingDir, A_ScriptDir, A_ScriptName, (...more...)
- Date and Time: A_YYYY, A_MM, A_DD, A_Hour, A_Min, A_Sec, (...more...)
- Script Settings: A_IsSuspended, A_BatchLines, A_TitleMatchMode, (...more...)
- User Idle Time: A_TimeIdle, A_TimeIdlePhysical
- GUI Windows and Menu Bars: A_Gui, A_GuiControl, A_GuiEvent, A_EventInfo
- Hotkeys, Hotstrings, and Custom Menu Items: A_ThisHotkey, A_EndChar, A_ThisMenuItem, (...more...)
- Operating System and User Info: A_OSVersion, A_ScreenWidth, A_ScreenHeight, (...more...)
- Misc: A_Cursor, A_CaretX, A_CaretY, Clipboard, ClipboardAll, ErrorLevel
- Loop: A_Index, (...more...)
Special Characters
A_Space | This variable contains a single space character. See AutoTrim for details. |
A_Tab | This variable contains a single tab character. See AutoTrim for details. |
Script Properties
1, 2, 3, etc. | These variables are automatically created whenever a script is launched with command line parameters. They can be changed and referenced just like normal variable names (for example: %1%). The variable %0% contains the number of parameters passed (0 if none). For details, see the command line parameters. |
A_WorkingDir | The script's current working directory, which is where files will be accessed by default. The final backslash is not included unless it is the root directory. Two examples: C:\ and C:\My Documents. Use SetWorkingDir to change the working directory. |
A_ScriptDir | The full path of the directory where the current script is located. For backward compatibility with AutoIt v2, the final backslash is included only for .aut scripts (even for root directories). An example for .aut scripts is C:\My Documents\ |
A_ScriptName | The file name of the current script, without its path, e.g. MyScript.ahk. |
A_ScriptFullPath | The combination of the above two variables to give the complete file specification of the script, e.g. C:\My Documents\My Script.ahk |
A_LineNumber |
The number of the currently executing line within the script (or one of its #Include files). This line number will match the one shown by ListLines; it can be useful for error reporting such as this example: MsgBox Could not write to log file (line number %A_LineNumber%). Since a compiled script has merged all its #Include files into one big script, its line numbering may be different than when it is run in non-compiled mode. |
A_LineFile | The full path and name of the file to which A_LineNumber belongs, which will be the same as A_ScriptFullPath unless the line belongs to one of a non-compiled script's #Include files. |
A_ThisFunc [v1.0.46.16+] |
The name of the user-defined function that is currently executing (blank if none); for example: MyFunction. See also: IsFunc() |
A_ThisLabel [v1.0.46.16+] |
The name of the label (subroutine) that is currently executing (blank if none); for example: MyLabel. It is updated whenever the script executes Gosub/Return or Goto. It is also updated for automatically-called labels such as timers, GUI threads, menu items, hotkeys, hotstrings, OnClipboardChange, and OnExit, However, A_ThisLabel is not updated when execution "falls into" a label from above; when that happens, A_ThisLabel retains its previous value. See also: A_ThisHotkey and IsLabel() |
A_AhkVersion | In versions prior to 1.0.22, this variable is blank. Otherwise, it contains the version of AutoHotkey that is running the script, such as 1.0.22. In the case of a compiled script, the version that was originally used to compile it is reported. The formatting of the version number allows a script to check whether A_AhkVersion is greater than some minimum version number with > or >= as in this example: if A_AhkVersion >= 1.0.25.07 |
A_AhkPath |
For non-compiled scripts: The full path and name of the EXE file that is actually running the current script. For example: C:\Program Files\AutoHotkey\AutoHotkey.exe For compiled scripts: The same as the above except the AutoHotkey directory is discovered via the registry entry HKEY_LOCAL_MACHINE\SOFTWARE\AutoHotkey\InstallDir. If there is no such entry, A_AhkPath is blank. |
A_IsCompiled | Contains 1 if the script is running as a compiled EXE and nothing if it is not. |
A_ExitReason | The most recent reason the script was asked to terminate. This variable is blank unless the script has an OnExit subroutine and that subroutine is currently running or has been called at least once by an exit attempt. See OnExit for details. |
Date and Time
A_YYYY | Current 4-digit year (e.g. 2004). Synonymous with A_Year. Note: To retrieve a formatted time or date appropriate for your locale and language, use "FormatTime, OutputVar" (time and long date) or "FormatTime, OutputVar,, LongDate" (retrieves long-format date). |
A_MM | Current 2-digit month (01-12). Synonymous with A_Mon. |
A_DD | Current 2-digit day of the month (01-31). Synonymous with A_MDay. |
A_MMMM | Current month's full name in the current user's language, e.g. July |
A_MMM | Current month's abbreviation in the current user's language, e.g. Jul |
A_DDDD | Current day of the week's full name in the current user's language, e.g. Sunday |
A_DDD | Current day of the week's 3-letter abbreviation in the current user's language, e.g. Sun |
A_WDay | Current 1-digit day of the week (1-7). 1 is Sunday in all locales. |
A_YDay | Current day of the year (1-366). The value is not zero-padded, e.g. 9 is retrieved, not 009. To retrieve a zero-padded value, use the following: FormatTime, OutputVar, , YDay0 |
A_YWeek | Current year and week number (e.g. 200453) according to ISO 8601. To separate the year from the week, use StringLeft, Year, A_YWeek, 4 and StringRight, Week, A_YWeek, 2. Precise definition of A_YWeek: If the week containing January 1st has four or more days in the new year, it is considered week 1. Otherwise, it is the last week of the previous year, and the next week is week 1. |
A_Hour | Current 2-digit hour (00-23) in 24-hour time (for example, 17 is 5pm). To retrieve 12-hour time as well as an AM/PM indicator, follow this example: FormatTime, OutputVar, , h:mm:ss tt |
A_Min | |
A_Sec | Current 2-digit second (00-59). |
A_MSec | Current 3-digit millisecond (000-999). To remove the leading zeros, follow this example: Milliseconds := A_MSec + 0 |
A_Now | The current local time in YYYYMMDDHH24MISS format. Note: Date and time math can be performed with EnvAdd and EnvSub. Also, FormatTime can format the date and/or time according to your locale or preferences. |
A_NowUTC | The current Coordinated Universal Time (UTC) in YYYYMMDDHH24MISS format. UTC is essentially the same as Greenwich Mean Time (GMT). |
A_TickCount |
The number of milliseconds since the computer was rebooted. By storing A_TickCount in a variable, elapsed time can later be measured by subtracting that variable from the latest A_TickCount value. For example: StartTime := A_TickCount Sleep, 1000 ElapsedTime := A_TickCount - StartTime MsgBox, %ElapsedTime% milliseconds have elapsed. If you need more precision than A_TickCount's 10ms, use QueryPerformanceCounter(). |
Script Settings
A_IsSuspended | Contains 1 if the script is suspended and 0 otherwise. |
A_IsPaused [v1.0.48+] |
Contains 1 if the thread immediately underneath the current thread is paused. Otherwise it contains 0. |
A_IsCritical [v1.0.48+] |
Contains 0 if Critical is off for the current thread. Otherwise it contains an integer greater than zero, namely the message-check frequency being used by Critical. Since "Critical 0" turns off critical, the current state of Critical can be saved and restored via Old_IsCritical := A_IsCritical followed later by Critical %Old_IsCritical% |
A_BatchLines | (synonymous with A_NumBatchLines) The current value as set by SetBatchLines. Examples: 200 or 10ms (depending on format). |
A_TitleMatchMode | The current mode set by SetTitleMatchMode: 1, 2, 3, or RegEx. |
A_TitleMatchModeSpeed | The current match speed (fast or slow) set by SetTitleMatchMode. |
A_DetectHiddenWindows | The current mode (On or Off) set by DetectHiddenWindows. |
A_DetectHiddenText | The current mode (On or Off) set by DetectHiddenText. |
A_AutoTrim | The current mode (On or Off) set by AutoTrim. |
A_StringCaseSense | The current mode (On, Off, or Locale) set by StringCaseSense. |
A_FormatInteger | The current integer format (H or D) set by SetFormat. |
A_FormatFloat | The current floating point number format set by SetFormat. |
A_KeyDelay | The current delay set by SetKeyDelay (always decimal, not hex). This delay is for the traditional SendEvent mode, not SendPlay. |
A_WinDelay | The current delay set by SetWinDelay (always decimal, not hex). |
A_ControlDelay | The current delay set by SetControlDelay (always decimal, not hex). |
A_MouseDelay | The current delay set by SetMouseDelay (always decimal, not hex). This delay is for the traditional SendEvent mode, not SendPlay. |
A_DefaultMouseSpeed | The current speed set by SetDefaultMouseSpeed (always decimal, not hex). |
A_IconHidden | Contains 1 if the tray icon is currently hidden or 0 otherwise. The icon can be hidden via #NoTrayIcon or the Menu command. |
A_IconTip | Blank unless a custom tooltip for the tray icon has been specified via Menu, Tray, Tip -- in which case it's the text of the tip. |
A_IconFile | Blank unless a custom tray icon has been specified via Menu, tray, icon -- in which case it's the full path and name of the icon's file. |
A_IconNumber | Blank if A_IconFile is blank. Otherwise, it's the number of the icon in A_IconFile (typically 1). |
User Idle Time
A_TimeIdle | The number of milliseconds that have elapsed since the system last received keyboard, mouse, or other input. This is useful for determining whether the user is away. This variable will be blank unless the operating system is Windows 2000, XP, or beyond. Physical input from the user as well as artificial input generated by any program or script (such as the Send or MouseMove commands) will reset this value back to zero. Since this value tends to increase by increments of 10, do not check whether it is equal to another value. Instead, check whether it is greater or less than another value. For example: IfGreater, A_TimeIdle, 600000, MsgBox, The last keyboard or mouse activity was at least 10 minutes ago. |
A_TimeIdlePhysical |
Similar to above but ignores artificial keystrokes and/or mouse clicks whenever the corresponding hook (keyboard or mouse) is installed; that is, it responds only to physical events. (This prevents simulated keystrokes and mouse clicks from falsely indicating that a user is present.) If neither hook is installed, this variable is equivalent to A_TimeIdle. If only one hook is installed, only its type of physical input affects A_TimeIdlePhysical (the other/non-installed hook's input, both physical and artificial, has no effect). |
GUI Windows and Menu Bars
A_Gui | The GUI window number that launched the current thread. This variable is blank unless a Gui control, menu bar item, or event such as GuiClose/GuiEscape launched the current thread. |
A_GuiControl | The name of the variable associated with the GUI control that launched the current thread. If that control lacks an associated variable, A_GuiControl instead contains the first 63 characters of the control's text/caption (this is most often used to avoid giving each button a variable name). A_GuiControl is blank whenever: 1) A_Gui is blank; 2) a GUI menu bar item or event such as GuiClose/GuiEscape launched the current thread; 3) the control lacks an associated variable and has no caption; or 4) The control that originally launched the current thread no longer exists (perhaps due to Gui Destroy). |
A_GuiWidth A_GuiHeight |
These contain the GUI window's width and height when referenced in a GuiSize subroutine. They apply to the window's client area, which is the area excluding title bar, menu bar, and borders. |
A_GuiX A_GuiY |
These contain the X and Y coordinates for GuiContextMenu and GuiDropFiles events. Coordinates are relative to the upper-left corner of the window. |
A_GuiEvent or A_GuiControlEvent |
The type of event that launched the current thread. If the thread was not launched via GUI action, this variable is blank. Otherwise, it contains one of the following strings: Normal: The event was triggered by a single left-click or via keystrokes (arrow keys, TAB key, space bar, underlined shortcut key, etc.). This value is also used for menu bar items and the special events such as GuiClose and GuiEscape. DoubleClick: The event was triggered by a double-click. Note: The first click of the click-pair will still cause a Normal event to be received first. In other words, the subroutine will be launched twice: once for the first click and again for the second. RightClick: Occurs only for GuiContextMenu, ListViews, and TreeViews. Context-sensitive values: For details see GuiContextMenu, GuiDropFiles, Slider, MonthCal, ListView, and TreeView. |
A_EventInfo |
Contains additional information about the following events:
|
Note: Unlike variables such as A_ThisHotkey, each thread retains its own value for A_Gui, A_GuiControl, A_GuiX/Y, A_GuiEvent, and A_EventInfo. Therefore, if a thread is interrupted by another, upon being resumed it will still see its original/correct values in these variables.
Hotkeys, Hotstrings, and Custom Menu Items
A_ThisMenuItem | The name of the most recently selected custom menu item (blank if none). |
A_ThisMenu | The name of the menu from which A_ThisMenuItem was selected. |
A_ThisMenuItemPos | A number indicating the current position of A_ThisMenuItem within A_ThisMenu. The first item in the menu is 1, the second is 2, and so on. Menu separator lines are counted. This variable is blank if A_ThisMenuItem is blank or no longer exists within A_ThisMenu. It is also blank if A_ThisMenu itself no longer exists. |
A_ThisHotkey |
The key name of the most recently executed hotkey or non-auto-replace hotstring (blank if none), e.g. #z. This value will change if the current thread is interrupted by another hotkey, so be sure to copy it into another variable immediately if you need the original value for later use in a subroutine. When a hotkey is first created -- either by the Hotkey command or a double-colon label in the script -- its key name and the ordering of its modifier symbols becomes the permanent name of that hotkey. See also: A_ThisLabel |
A_PriorHotkey | Same as above except for the previous hotkey. It will be blank if none. |
A_TimeSinceThisHotkey | The number of milliseconds that have elapsed since A_ThisHotkey was pressed. It will be -1 whenever A_ThisHotkey is blank. |
A_TimeSincePriorHotkey | The number of milliseconds that have elapsed since A_PriorHotkey was pressed. It will be -1 whenever A_PriorHotkey is blank. |
A_EndChar | The ending character that was pressed by the user to trigger the most recent non-auto-replace hotstring. If no ending character was required (due to the * option), this variable will be blank. |
Operating System and User Info
ComSpec [v1.0.43.08+] |
Contains the same string as the environment's ComSpec variable (e.g. C:\Windows\system32\cmd.exe). Often used with Run/RunWait. Note: there is no A_ prefix on this variable. |
A_Temp [v1.0.43.09+] |
The full path and name of the folder designated to hold temporary files (e.g. C:\DOCUME~1\UserName\LOCALS~1\Temp). It is retrieved from one of the following locations (in order): 1) the environment variables TMP, TEMP, or USERPROFILE; 2) the Windows directory. On Windows 9x, A_WorkingDir is returned if neither TMP nor TEMP exists. |
A_OSType | The type of Operating System being run. Either WIN32_WINDOWS (i.e. Windows 95/98/ME) or WIN32_NT (i.e. Windows NT4/2000/XP/2003/Vista). |
A_OSVersion |
One of the following strings: WIN_VISTA [requires v1.0.44.13+], WIN_2003, WIN_XP, WIN_2000, WIN_NT4, WIN_95, WIN_98, WIN_ME. For example: if A_OSVersion in WIN_NT4,WIN_95,WIN_98,WIN_ME ; Note: No spaces around commas.
{
MsgBox This script requires Windows 2000/XP or later.
ExitApp
} |
A_Language | The system's default language, which is one of these 4-digit codes. |
A_ComputerName | The name of the computer as seen on the network. |
A_UserName | The logon name of the user who launched this script. |
A_WinDir | The Windows directory. For example: C:\Windows |
A_ProgramFiles or ProgramFiles |
The Program Files directory (e.g. C:\Program Files). In v1.0.43.08+, the A_ prefix may be omitted, which helps ease the transition to #NoEnv. |
A_AppData [v1.0.43.09+] |
The full path and name of the folder containing the current user's application-specific data. For example: C:\Documents and Settings\Username\Application Data |
A_AppDataCommon [v1.0.43.09+] |
The full path and name of the folder containing the all-users application-specific data. |
A_Desktop | The full path and name of the folder containing the current user's desktop files. |
A_DesktopCommon | The full path and name of the folder containing the all-users desktop files. |
A_StartMenu | The full path and name of the current user's Start Menu folder. |
A_StartMenuCommon | The full path and name of the all-users Start Menu folder. |
A_Programs | The full path and name of the Programs folder in the current user's Start Menu. |
A_ProgramsCommon | The full path and name of the Programs folder in the all-users Start Menu. |
A_Startup | The full path and name of the Startup folder in the current user's Start Menu. |
A_StartupCommon | The full path and name of the Startup folder in the all-users Start Menu. |
A_MyDocuments | The full path and name of the current user's "My Documents" folder. Unlike most of the similar variables, if the folder is the root of a drive, the final backslash is not included. For example, it would contain M: rather than M:\ |
A_IsAdmin |
If the current user has admin rights, this variable contains 1. Otherwise, it contains 0. Under Windows 95/98/Me, this variable always contains 1. On Windows Vista or later, some scripts might require administrator privileges to function properly (such as a script that interacts with a process or window that is run as administrator). To achieve this, add the following at the top of the script (this would need to be enhanced to work for compiled scripts and/or to pass parameters): if not A_IsAdmin { DllCall("shell32\ShellExecuteA", uint, 0, str, "RunAs", str, A_AhkPath , str, """" . A_ScriptFullPath . """", str, A_WorkingDir, int, 1) ExitApp } |
A_ScreenWidth |
The width and height of the primary monitor, in pixels (e.g. 1024 and 768). To discover the dimensions of other monitors in a multi-monitor system, use SysGet. To instead discover the width and height of the entire desktop (even if it spans multiple monitors), use the following example (but on Windows 95/NT, both of the below variables will be set to 0): In addition, use SysGet to discover the work area of a monitor, which can be smaller than the monitor's total area because the taskbar and other registered desktop toolbars are excluded. |
A_IPAddress1 through 4 | The IP addresses of the first 4 network adapters in the computer. |
Misc.
A_Cursor |
The type of mouse cursor currently being displayed. It will be one of the following words: AppStarting, Arrow, Cross, Help, IBeam, Icon, No, Size, SizeAll, SizeNESW, SizeNS, SizeNWSE, SizeWE, UpArrow, Wait, Unknown. The acronyms used with the size-type cursors are compass directions, e.g. NESW = NorthEast+SouthWest. The hand-shaped cursors (pointing and grabbing) are classified as Unknown. Known limitation on Windows 95: If this variable's contents are fetched repeatedly at a high frequency (i.e. every 500 ms or faster), it will probably disrupt the user's ability to double-click. There is no known workaround. |
A_CaretX A_CaretY |
The current X and Y coordinates of the caret (text insertion point). The coordinates are relative to the active window unless CoordMode is used to make them relative to the entire screen. If there is no active window or the caret position cannot be determined, these variables are blank. The following script allows you to move the caret around to see its current position displayed in an auto-update tooltip. Note that some windows (e.g. certain versions of MS Word) report the same caret position regardless of its actual position. #Persistent If the contents of these variables are fetched repeatedly at a high frequency (i.e. every 500 ms or faster), the user's ability to double-click will probably be disrupted. There is no known workaround. |
Clipboard | The contents of the OS's clipboard, which can be read or written to. See the Clipboard section. |
ClipboardAll | The entire contents of the clipboard (such as formatting and text). See ClipboardAll. |
ErrorLevel | See ErrorLevel. |
A_LastError | The result from the OS's GetLastError() function. For details, see DllCall() and Run/RunWait. |
Loop
A_Index | This is the number of the current loop iteration (a 64-bit integer). For example, the first time the script executes the body of a loop, this variable will contain the number 1. For details see Loop or While-loop. |
A_LoopFileName, etc. | This and other related variables are valid only inside a file-loop. |
A_LoopRegName, etc. | This and other related variables are valid only inside a registry-loop. |
A_LoopReadLine | See file-reading loop. |
A_LoopField | See parsing loop. |
Environment Variables vs. "Normal" Variables
Environment variables are maintained by the operating system. You can see a list of them at the command prompt by typing SET then pressing Enter.
A script may create a new environment variable or change the contents of an existing one with EnvSet. However, such additions and changes are private; they are not seen by the rest of the system. One exception is when a script uses Run or RunWait to launch a program (even another script): such programs inherit a copy of the parent script's environment variables, including private ones.
In v1.0.43.08+, it is recommended that all new scripts retrieve environment variables such as Path via:
EnvGet, OutputVar, Path ; For explanation, see #NoEnv.
Variable Capacity and Memory
- Each variable may contain up to 64 MB of text (this limit can be increased with #MaxMem).
- When a variable is given a new string longer than its current contents, additional system memory is allocated automatically.
- The memory occupied by a large variable can be freed by setting it equal to nothing, e.g. var := ""
- There is no limit to how many variables a script may create. The program is designed to support at least several million variables without a significant drop in performance.
- Commands, functions, and expressions that accept numeric inputs generally support 15 digits of precision for floating point values. For integers, 64-bit signed values are supported, which range from -9223372036854775808 (-0x8000000000000000) to 9223372036854775807 (0x7FFFFFFFFFFFFFFF). Any integer constants outside this range are not supported and might yield inconsistent results. By contrast, arithmetic operations on integers wrap around upon overflow (e.g. 0x7FFFFFFFFFFFFFFF + 1 = -0x8000000000000000).